UL Standards: Don’t forget the cables

Jack Noel, Regional Sales Manager at Lutze talks us through the importance of cabling in relation to UL.

Cabling can often be relegated to an afterthought for OEMs and machine builders looking to supply into the North American market. With the control panels built and the components selected, all under UL guidance, machine connectivity will bring the whole thing together but there’s a serious worry that all that hard work can be undone by not understanding the importance of cabling in relation to UL.

Getting cabling wrong can cause a number of unique electrical issues that are unlike any other in machine applications. There are often high demands on cable connectivity, so machine builders unlocking growth potential and thinking about expanding into the US market will want to steer clear of the operating malfunctions and early failures that often stall progress.

cabling ul standards

VFD (variable frequency drives) is one area of focus for machine builders and NFPA 79 outlines everything you may need to know to be fully compliant but it’s no walk in the park. As we have instigated throughout this UL standards blog series, the cost of getting UL wrong, no matter what stage of the build can be disastrous. Cabling is no different, so what considerations need to be understood and applied to make sure your machine is fit for North American markets?

Cabling for the USA

When considering cable requirements for machines destined for the USA there are two standards that needs to be considered in the construction and installation of the machine: NEC 79 and NEC 80.

NEC 80 is the equivalent of the UK Wiring regulations covering electrical installations in all types of buildings. To conform with this standard any cables running within the building connecting to the machine should be UL listed and verified for the intended use. The markings below indicate listed cables.

ul standards logos

NFPA 79 is the Electrical Standard for Industrial Machinery in the USA. NFPA 79 is the section of the National Electric Code (NEC®) that focuses on the electrical wiring standards used with industrial machinery. NFPA 79 applies to the electrical equipment used within a wide variety of machines, as well as groups of machines working together in a coordinated manner.

NFPA 79 is an extremely important industry-specific standards in North America and has special provisions addressing safe wiring practices for industrial machinery, such as machine tools. A common concern in automation applications is the use of Appliance Wiring Material (AWM) as opposed to using UL listed cables.

In order to use Appliance Wiring Material on industrial machinery and be compliant with NFPA 79, the cable must accommodate one of three provisions stated in article 12.9 of the NFPA 79 standard. It is important to note that it is sufficient to comply with just one of the three conditions instead of having to meet their requirements in combination. The conditions are as follows:

  1. It is permissible to use AWM cable or conductors if part of a listed assembly identified for the intend use.
  2. Or it is permissible to use AWM cable or conductors where the AWM has been identified for use with approved equipment and is used in accordance with the equipment manufacturer’s instructions. One example would be a servo drive system with a cable assembly made per the servo drive system manufacturer’s specification and installed per the manufacturer’s instructions.
  3. Or it is permissible to use AWM cable or conductors where its construction meets all applicable requirements of Section 12.2 through Section 12.6 with some modifications. These modifications set requirements in terms of construction, flame resistance, insulation and voltage ratings as well as marking and print legends for clear identification. This will allow those types of AWM cables which are suitable for industrial use by their nature. However, it will control the misuse of AWM cables which do not meet industrial application requirements, e.g. voltage rating, insulation thickness, oil resistance, etc.

Appliance Wiring Material is regulated by UL 758 and carries the UL Recognised logo

ul recognised logo

VFD and specific cable selection

Variable Frequency Drive applications can cause unique electrical issues that are unlike other standard power transmission in machine applications. There are higher demands on the cable connecting the motor to the drive. Standard multi-conductor cables rated for 500V will most likely not meet the requirements of VFD applications and can cause operating malfunctions and early failures. Cable is often an afterthought in the planning process but represents actually a very important component in the whole application.

ul standards ul listed cable

The deployment of VFD (Variable Frequency Drives) products is increasing rapidly in the USA. The 3-phase voltage varies across the country, it is therefore important to select the correct cable for the application, particularly when running a long length of cable.

Let’s look at a specific example:

ul standards eg1
ul standards eg2

With an input of 400V, the drive would have an actual output of 560V DC. A 480V drive would have an output of 650V DC directly on the drive terminals. Diagram B shows the voltage that can be present after the power distortions are amplified through the cable. These reflected pulses can combine to raise the voltage on the cable as shown above. This effect is exaggerated by cable length. High voltage spikes can lead to insulation breakdown on the cable resulting in short circuits.

Conventional thermoplastic insulated cables (PVC) should not be used in VFD applications as they cannot withstand these voltages and have a higher capacitance between cores.

A typical VFD cable should have a 600/1000V rating which is standard for servo motor cables. The same rating should be considered for Invertor type applications particularly where the drive is located some distance from the motor.

There’s a simple way of getting cabling right

Lutze have extensive experience in selecting cables for automation applications in the USA. We welcome involvement at the design phase to assist customers in meeting the correct standards and avoid the headaches often caused later in the build and component/wiring selection phases.

All Lutze AWM cables are designed for use in industrial environments and the AWM style and voltage rating is clearly marked on each cable jacket. However, for field installation it will still be safest to rely on cable that is UL Listed and verified for the intended use as required by the NEC.

Lutze offers many listed types, including MTW, TC-ER, PLTC and CM marks. Cables with these markings are considered listed types and are always permitted to be used in NFPA 79 compliant applications, as well as in applications per NEC.

The simplest way to get cabling right is to consult an expert like those employed at Lutze and its technical partners, some of which are involved in this blog series and can guide you under every facet of UL certification.

Stay in the loop

Come back next week when the blog series will be finalised by guest contributor Mark Lindsey of Product Approvals, also delivering a video from home detailing UL inspection and evaluation.

If you have a specific question about UL then the form below will be the most useful tool for you. With these questions, we can respond to your specific needs directly and also build on the communications planned throughout the campaign.

To be notified of any updates in the campaign, navigate to the sign-up form below.

Ask us any question you have on UL Standards

With these questions, we can respond to your specific needs directly and also build on the communications planned over the coming weeks.







Sign up for UL Standards campaign updates






Share.

Connect.

Subscribe

More thought-leading content

Unlock your growth potential. Explore key services

Do you outsource?

Realise your growth potential by making outsourcing part of your manufacturing strategy.


At PP C&A, we never assume that a solution for one customer will work for another, because every customer is unique. That is why we will never try to simply sell you an ‘off the shelf solution’.


We believe in meeting you, listening and understanding your needs first. If you are considering outsourcing for the first time or you wish to review your current outsourcing strategies, we would welcome the opportunity for discussion





1. Do you outsource?

If yes
Do you outsource to multiple suppliers?

2. Are you considering outsourcing or considering changing supplier?
3. Are you experiencing barriers to growth?


4. Would you like to arrange a consultation (call or visit) with us?
5. Would you like to receive more information on strategic outsourcing?
6. If you have a more specific enquiry, question or pain point, please let us know: